Dade County Approval: AW Series wall panels have been approved for use in High Velocity Hurricane Zones by the Miami-Dade Product Control Division. N.O.A. 03-0429.01
Fire Performance: Metecno USA-ASI Division polyiso core panels have passed the FM Approvals Full scale corner test, FM 4880, along with ASTM E84 and D1929 to qualify for Class 1 Rating with no height restriction. These results indicate that buildings utilizing Metecno USA-ASI Division polyiso panels on walls and/or ceilings do not require a sprinkler system of themselves, qualifying the building for reduced insurance premiums.
Thermal Transmission: Metecno USA-ASI Division panels have been tested for insulating values in accordance with ASTM C518, ASTM C236 and ASTM C1316 test methods. Results from individual panel types are available.
Air Infiltration: Panel joints have been tested for air infiltration in accordance with ASTM E283. Results for individual panel types are available.
Water Penetration: Panel joints have been tested for water penetration in accordance with ASTM E331. Results for individual panel types are Available.
Structural: Metecno USA-ASI Division roof panel products are classified by Factory Mutual as to FM1-90 wind uplift. Wall panels have been tested as to wind pressure resistance according to spans. Results for individual panel types are available.